MP5W-41 – Tachometer With Relay
$34.8
$41.76
Description Display method 5-digit 7-segment LED Character height 14mm Max. display Range -19999 to 99999 Measurement 16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc. Measurement range 0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999 Input method Voltage input(PNP), No-voltage input(NPN) Power supply 100-240VAC~ 50/60Hz External Power Supply Max. 12VDC ±10% 80mA Output_Main Output(Comparative Value) Relay (H, GO, L) Input frequency ·Solid state input 1: max. 50kHz (pulse width: min. 10㎲) ·Solid state input 2: max. 5kHz (pulse width: min. 100㎲) ※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲) ·Contact input: max. 45Hz (pulse width: min. 11ms) Measurement range ·Operation mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz ·Operation mode F3, F4, F5, F6 : 0.01 to max. of each time range ·Operation mode F11, F12, F13, F16 : 0 to 99999 ·Operation mode F14, F15 : -19999 to 99999 Measurement accuracy ·Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.05%rdg±1-digit ·Operation mode F3, F4, F5, F6 : F.S.±0.01%rdg±1-digit Prescale function Direct input method (0.0001×10-9 to 9.9999×109) Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Weight Approx. 334g (approx. 210g) Protection structure IP54 (front part, IEC standard) ※Hysteresis: Setting range will vary depending on the decimal point. ※The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation.
Autonics